Please use this identifier to cite or link to this item:
http://essuir.sumdu.edu.ua/handle/123456789/27857
Or use following links to share this resource in social networks:
Tweet
Recommend this item
Title | Room temperature ammonia gas sensing characteristics of Co3O4 |
Authors |
Shelke, P.N.
Jadkar, S.R. Khollam, Y.B. Chakane, S.D. Adsool, A.D. Mohite, K.C. |
ORCID | |
Keywords |
датчик аммиака датчик аміаку ammonia sensor чутливість чувствительность sensitivity воспроизводимость відтворюваність repeatbility response & recovery time |
Type | Article |
Date of Issue | 2011 |
URI | http://essuir.sumdu.edu.ua/handle/123456789/27857 |
Publisher | Видавництво СумДУ |
License | |
Citation | Room temperature ammonia gas sensing characteristics of Co3O4 [Текст] / P.N. Shelke, S.R. Jadkar, Y.B. Khollam et al. // Journal of Nano- and Electronic Physics. — 2011. — Vol. 3, № 1, Part V : Proceedings of the International Symposium on Semiconductor Materials and Devices (ISSMD-2011), Vadodara, India, 28-30 January 2011. — P. 859-867. |
Abstract |
Room temperature ammonia gas-sensing characteristics of Co3O4 pellet sensor are
reported in this paper. For this purpose, Co3O4 powder is prepared by a route of simple
precipitation + heating at 800° C/2 hr. The as-prepared powder is characterized by
using X-ray diffraction and scanning electron microscopy. The ammonia gas-sensing
properties of Co3O4 pellets made at various loads of 3, 5, 7 & 9 ton and at constant
time 4 min. are measured using home-built static gas sensing system. The
characterization studies revealed that the cobalt oxide particles formed are cubic
spinel Co3O4, highly pure and spherical in shape. The particle size distribution is
found to be nearly uniform with average particle size ~ 1 μm. The ammonia gas
sensing properties of Co3O4 pellet sensor are found to be good. The highest
sensitivities – S.F. 175 and 358 are found at ~ 25 ppm and 250 ppm concentrations
of ammonia gas respectively for the Co3O4 pellet sensor made at the load 3 ton.
Further, an admirable repeatability and reversibility in the ammonia gas sensing
characteristics are observed for all the Co3O4 pellet sensors. The average response time
of 4.0 min. and recovery time of 3.0 min. are obtained for all the Co3O4 pellet sensors.
When you are citing the document, use the following link http://essuir.sumdu.edu.ua/handle/123456789/27857 |
Appears in Collections: |
Журнал нано- та електронної фізики (Journal of nano- and electronic physics) |
Views
Belarus
1
Canada
3
China
1070682869
Germany
430875
Greece
1
India
42424444
Indonesia
-1774837217
Iran
1
Ireland
5940143
Italy
2
Japan
21212224
Lithuania
1
Mongolia
1
Netherlands
53863
Poland
1
Romania
1
Russia
22
Singapore
1
Slovakia
1
South Korea
2548344
Spain
1
Sweden
1
Thailand
1341412556
Turkey
8681
Ukraine
230642441
United Kingdom
115375080
United States
-541459363
Unknown Country
230642440
Vietnam
215438
Downloads
China
-1612142195
Czechia
1
France
1
Germany
320
India
1704886
Indonesia
4
Ireland
1
Italy
1
Lithuania
1
Morocco
1
Peru
1
Singapore
-1774837216
South Africa
1
Thailand
1
Ukraine
230642442
United States
745292857
Unknown Country
128
Vietnam
1
Files
File | Size | Format | Downloads |
---|---|---|---|
Shelke.pdf | 1.23 MB | Adobe PDF | 1885628532 |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.