Please use this identifier to cite or link to this item:
http://essuir.sumdu.edu.ua/handle/123456789/35363
Or use following links to share this resource in social networks:
Tweet
Recommend this item
Title | Effects of Deuterium Implantation Dose on Hardness and Deuterium Desorption Temperature Range from High Entropy TiVZrNbHf and TiVZrNbHfN Coatings |
Authors |
Kuprin, A.S.
Morozov, O.M. Belous, V.A. Firstov, S.A. Gorban, V.F. Ovcharenko, V.D. Reshetnyak, E.N. Tolmachova, G.N. Zhurba, V.I. Progolaieva, V.O. |
ORCID | |
Keywords |
High-entropy composites Deuterium Hardness Thermal desorption spectroscopy (TDS) Implantation |
Type | Conference Papers |
Date of Issue | 2013 |
URI | http://essuir.sumdu.edu.ua/handle/123456789/35363 |
Publisher | Sumy State University |
License | Copyright not evaluated |
Citation | Effects of Deuterium Implantation Dose on Hardness and Deuterium Desorption Temperature Range from High Entropy TiVZrNbHf and TiVZrNbHfN Coatings [Текст] / A.S. Kuprin, O.M. Morozov, V.A. Belous et al. // Nanomaterials: Applications & Properties (NAP-2013) : 3-rd International conference, Alushta, the Crimea, Ukraine, September 16-21, 2013 / Edited by: A. Pogrebnjak. - Sumy : Sumy State University, 2013. - V.2, No2. - 02FNC20 |
Abstract |
High entropy TiVZrNbHf and TiVZrNbHfN coatings prepared by filtered vacuum arc plasma from a single
equiatomic HEA cathode. Similarly were obtained titanium and titanium nitride coatings. The structure
of coatings was investigated by X-ray analysis and the changes in nanohardness by nanoindentation method.
The effusion of the implanted deuterium was studied by thermal desorption spectroscopy (TDS).
It is shown that the structure of effusion spectrum is a function of deuterium dose. With increasing implantation
dose deuterium desorption temperature range from coatings is expanding in the direction of
lowering the temperature and the temperature of the peak maximum gas emission gradually shifts to lower
temperatures. For nitride coatings deuterium desorption starts at about room temperature and the maximum
rate of desorption at a temperature of ~500 K.
When irradiation doses more than 5×1017 D/cm2 hardness of nitride coatings decreased by half. Hardness
reduction of coatings is caused by occurrence hydride structural formations in coatings.
When you are citing the document, use the following link http://essuir.sumdu.edu.ua/handle/123456789/35363 |
Appears in Collections: |
Наукові видання (ЕлІТ) |
Views

1

1

1

933402916

-678136305

1

1609837

1

233561321

1

1

1

7

1866805826

3221

2

40751230

21864653

-1367217822

1093409010

12886
Downloads

1

1866805825

2

1

1

116780660

1

-678136304

49

1

1
Files
File | Size | Format | Downloads |
---|---|---|---|
princon_2013_2_2_68.pdf | 435.33 kB | Adobe PDF | 1305450238 |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.