Please use this identifier to cite or link to this item:
https://essuir.sumdu.edu.ua/handle/123456789/77500
Or use following links to share this resource in social networks:
Tweet
Recommend this item
Title | Thermodynamic and Economic Evaluation of Gas Turbine Power Plants |
Authors |
Oyegoke, T.
Akanji, O.I. Ajayi, O.O. Obajulu, E.A. Abemi, A.O. |
ORCID | |
Keywords |
energy conversion system gas turbine economic analysis second law analysis power plant |
Type | Article |
Date of Issue | 2020 |
URI | https://essuir.sumdu.edu.ua/handle/123456789/77500 |
Publisher | Sumy State University |
License | |
Citation | Oyegoke T., Akanji I. I., Ajayi O. O., Obajulu E. A., Abemi A. O. (2020). Thermodynamic and Economic Evaluation of Gas Turbine Power Plants. Journal of Engineering Sciences, Vol. 7(1), pp. G1–G8, doi: 10.21272/jes.2020.7(1).g1 |
Abstract |
Thermodynamic analysis and economic feasibility of a gas turbine power plant using a theoretical approach are studied here. The operating conditions of Afam Gas Power Plant, Nigeria are utilized. A modern gas turbine power plant is composed of three key components which are the compressor, combustion chamber, and turbine. The plants were analyzed in different control volumes, and plant performance was estimated by component-wise modeling. Mass and energy conservation laws were applied to each component, and a complete energy balance conducted for each component. The lost energy was calculated for each control volume, and cumulative performance indices such as thermal efficiency and power output were also calculated. The profitability of the proposed project was analyzed using the Return on Investment (ROI), Net Present Worth (NPW), Payback Period (PBP), and Internal Rate of Return (IRR). First law analysis reveals that 0.9 % of the energy supplied to the compressor was lost while 99.1 %
was adequately utilized. 7.0 % energy was generated within the Combustion Chamber as a result of the combustion reaction, while 33.2 % of the energy input to the Gas Turbine was lost, and 66.8 % was adequately converted to shaft work which drives both compressor and electric generator. Second law analysis shows that the combustion chamber unit recorded lost work of 248.27 MW (56.1 % of the summation), and 77.33 MW (17.5 % of the summation) for Gas Turbine, while air compressor recorded 11.8 MW (2.7 %). Profitability analysis shows that the investment criteria are sensitive to change in the price of natural gas. Selling electricity at the current price set by the Nigerian Electricity Regulation Commission (NERC) at zero subsidies and an exchange rate of 365 NGN/kWh is not profitable, as the analysis of the investment gave an infinite payback period. The investment becomes profitable only at a 45 % subsidy regime. |
Appears in Collections: |
Journal of Engineering Sciences / Журнал інженерних наук |
Views
Australia
-1448193413
Bangladesh
1
Brazil
1617563441
Canada
1
China
455916748
France
97963
Germany
1398580469
Ghana
216405723
Greece
1
Hong Kong SAR China
1
India
800865672
Indonesia
1398580473
Iran
2122815827
Iraq
455916750
Ireland
421525333
Japan
-2041083979
Kenya
1741
Lithuania
1
Mexico
1
Netherlands
4022
Nigeria
1398580472
Oman
1
Pakistan
234487
Russia
421525331
Singapore
800865666
South Korea
2077022269
Sweden
1
Taiwan
1
Thailand
1
Uganda
1
Ukraine
800865677
United Kingdom
164394
United States
-2041083978
Unknown Country
800865676
Downloads
Australia
1
Bangladesh
1
Brazil
2599643
Canada
800865666
China
1
France
1
Germany
1312342728
India
-2041083977
Indonesia
54459
Iraq
1820955764
Kenya
1
Lithuania
1
Mexico
1
Nigeria
26903
Russia
1
Singapore
1398580474
South Korea
1
Taiwan
1
Uganda
1
Ukraine
111265
United Kingdom
1
United States
-2041083975
Files
File | Size | Format | Downloads |
---|---|---|---|
Oyegoke_jes_1_2020.pdf | 483.26 kB | Adobe PDF | 1253368962 |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.