Please use this identifier to cite or link to this item:
https://essuir.sumdu.edu.ua/handle/123456789/81237
Or use following links to share this resource in social networks:
Tweet
Recommend this item
Title | A New Solution for an Electrochemical Modification of Titanium Surface |
Other Titles |
Новий розчин для електрохімічної модифікації поверхні титану |
Authors |
Kyrylenko, Serhii Dmytrovych
Oleshko, Oleksandr Mykolaiovych Warchoł, F. Husak, Yevheniia Volodymyrivna Basiaga, M. Kazek-Kesik, A. Dercz, G. Pohorielov, Maksym Volodymyrovych Simka, W. |
ORCID |
http://orcid.org/0000-0003-2439-3243 http://orcid.org/0000-0002-2217-3717 http://orcid.org/0000-0001-9372-7791 |
Keywords |
плазмова електролітична оксидаці титан біоактивна поверхня дентальні імплантати біосумісність скануюча електронна мікроскопія енерго-дисперсійна спектроскопія контактний кут plasma electrolytic oxidation titanium bioactive surface dental implant biocompatibility scanning electron microscopy energy dispersive X-ray spectroscopy scratch test simulated body fluid test contact angle measurement |
Type | Article |
Date of Issue | 2020 |
URI | https://essuir.sumdu.edu.ua/handle/123456789/81237 |
Publisher | Sumy State University |
License | In Copyright |
Citation | S. Kyrylenko, O. Oleshko, F. Warchoł, et al., J. Nano- Electron. Phys. 12 No 6, 06038 (2020). DOI: https://doi.org/10.21272/jnep.12(6).06038 |
Abstract |
Дентальні та ортопедичні титанові імплантати є рутинним та доступним методом корекції в медичній практиці. Для подальшого підвищення безпеки та експлуатаційної довговічності досліджувались
чисельні підходи щодо формування біоактивного поверхневого шару, який має забезпечити як підвищення остеоінгетрації, так і зменшити ризик бактеріальної інфекції і формування бактеріальних біоплівок, які є предиктором розвитку периімплантитів. Плазмова електролітична оксидація (ПЕО) є перспективним методом формування біоактивного шару на металевих субстратах. Запропоновано різні протоколи ПЕО з метою досягнення кращої біосумісності дентальних імплантатів та підвищення їх стійкості до бактеріальних інфекцій, а також підвищення стійкості до корозії. При цьому процеси формування суцільних та пористих поверхневих шарів все ще потребують уточнення та детального вивчення. Попередні дослідження показали, що додавання хелатуючого агенту до електроліту призводить до кращих результатів, зокрема до формування пористої структури та підвищення функціональної здатності. В даному дослідження розкриті характеристики параметрів ПЕО з використанням електроліту, який містить інший широко використовуваний хелатуючий агент – нітрилотріоцтову кислоту (NTA), а також фосфат калію та формут кальцію. Отримані результати сприятимуть подальшому розумінню механізмів процесу ПEO та встановленню рутинних протоколів комерційної експлуатації методу. Dental/osseous implants manufactured of titanium (Ti) have become a routine and affordable method in medical practice. To increase the overall safety and longtime stability of the implants further, the sophisticated approaches have been investigated in order to supply the implants with the bioactive surface layers. They have to serve two purposes: to increase the osseointegration capacity of the implants and to reduce the chances of bacterial growth and formation of bacterial biofilms leading to periimplantitis. Plasma electrolytic oxidation (PEO) is becoming a promising method to introduce functionalized surface layers on a metal substrate. Various PEO protocols have been suggested in order to achieve better biocompatibility of the dental implants and to increase their resistance to bacterial infections. It was also suggested that the PEO layers could increase resistance to corrosion on the surfaces of metallic implants. The dynamic processes running on the surface of Ti during the PEO processing still require efforts to fully understand the molecular mechanisms of the formation of hard and porous oxide surface layers. We and others have already shown that addition of a chelating agent to the bath electrolyte leads to better outcomes in the morphology and functional characteristics of the implants. Here we report in depth characterization of the PEO parameters and the produced PEO surface layers using the bath electrolyte containing another widely used chelating agent, nitrilotriacetic acid (NTA) along with potassium phosphate and calcium formate. The results will contribute to further understanding the mechanisms of the PEO process and to establishing routine protocols for commercial exploitation of the PEO method. |
Appears in Collections: |
Журнал нано- та електронної фізики (Journal of nano- and electronic physics) |
Views
Australia
1
Bosnia & Herzegovina
1
Brazil
11627175
Canada
1
China
1719316674
France
1
Germany
527023
Greece
1
Hong Kong SAR China
1
Ireland
106451
Italy
1
Japan
1
Lithuania
1
Romania
1
Singapore
1
South Korea
1
Sweden
1
Turkey
1
Ukraine
203469873
United Kingdom
999512
United States
1300441702
Unknown Country
-1056479430
Vietnam
417
Downloads
Belgium
1
Canada
1
China
859658338
France
1
Germany
203469872
India
1
Ireland
38697
Japan
1300441704
Lithuania
1
Romania
1
Singapore
1
South Korea
203469875
Ukraine
5995711
United Kingdom
1
United States
-637604459
Unknown Country
1
Vietnam
1
Files
File | Size | Format | Downloads |
---|---|---|---|
Kyrylenko_jnep_6_2020.pdf | 950.73 kB | Adobe PDF | 1935469748 |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.