Abstract |
Безпека здоров'я людей є однією з найважливіших цілей урядів країн всього світу. Припинення
функціонування будь-якого органу людського тіла може призвести до негативного психологічного та
фізичного стану пацієнта. Заміна пошкодженого органу штучним у роботі розглянута на прикладі
плечового суглобу, повний протез якого може бути імплантований для відновлення функціонування
верхньої кінцівки. Правильний вибір матеріалів для такого протезування є одним із сучасних напрямів досліджень. Метою даної роботи є прогнозування поширення тріщини, штучно створеної в головці
плечового протеза. Плечовий протез складається з двох компонентів: головки, виготовленої, як правило, із нержавіючої сталі або металевих сплавів, та чашки, яка може бути виготовлена з поліетилену
з надвисокою молекулярною масою (UHMWPE). Запропонованим матеріалом головки є біокерамічний
глинозем, властивості якого роблять його перспективним матеріалом для заміни нержавіючої сталі
або металевих сплавів. Але найбільш небажаною властивістю глинозему є крихкість. Тому для дослідження міцності глинозему були попередньо штучно створені дефекти, а для розширення експерименту були розглянуті два випадки розташування попередньо створеної тріщини. Дослідження проводились методом моделювання з використанням коду обчислення кінцевих елементів Abaqus. Вихідні дані: реалізовано геометрію двох складів плечового протеза при навантаженні та вивчено механічні властивості розглянутого матеріалу. Отримані результати стосувались нормальних напружень на верхівці та лінії поширення попередньо створених тріщин. Для оцінки міцності глинозему проведено
розрахунок коефіцієнта інтенсивності напруженості. Остаточні результати у двох випадках виявляють можливість використання глинозему як матеріалу плечової вставки. The health safety of the human being is one of the most important goals of governments around the world. The cessation of the functioning of any organ of the human body would have a negative impact on psychological and physical health of the patient. The replacement of the damaged organ by an artificial organ is the used solution. The shoulder joint is an example; a total prosthesis can be implanted to recover the functioning of the upper limb. The right choice of materials for this prosthesis is one of the research directions today. The purpose of this work is to predict the propagation of the crack previously created in the head of the shoulder prosthesis. Shoulder prosthesis is composed of two components: a head made usually of inoxydable steel or metallic alloys and a cup which could be made of UHMWPE. The proposed material of the head was alumina. As bioceramics, alumina has known properties that make it a candidate material to replace used stainless steel or metallic alloys. But fragility is the most undesirable alumina property. So to investigate its tenacity prior defects were created and to extend the investigation two cases of remarkable location of the prior crack were considered. The selected mean of simulation is the finite element calculation code Abaqus. The needed data: geometries of the two compounds of the shoulder prosthesis, loads and mechanical properties of the considered material were implemented. The obtained results concerned normal stresses at the tip and the line of propagation of prior cracks. The calculation of intensity stress factor is necessary to judge alumina tenacity. Final results in the two cases reveal the possibility of using alumina as a material of the humeral insert. |
Appears in Collections: |
Журнал нано- та електронної фізики (Journal of nano- and electronic physics) |
Views
Algeria
16643
Argentina
1
China
1
Colombia
1
Germany
46120
Greece
1
Iran
4159
Ireland
167835
Lithuania
1
Poland
1
Singapore
1
Sweden
1
Turkey
3231766
Ukraine
889810
United Kingdom
327351
United States
29883399
Unknown Country
1
Vietnam
280
Downloads
Algeria
889811
Canada
1
China
15831473
Colombia
1
Germany
20515447
Ireland
16644
Japan
1
Lithuania
25199422
Ukraine
1779554
United Kingdom
1
United States
29883398
Vietnam
1
Files
File | Size | Format | Downloads |
---|---|---|---|
Belkacem_Meddour_jnep_6_2020.pdf | 396.75 kB | Adobe PDF | 94115754 |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.