Please use this identifier to cite or link to this item: https://essuir.sumdu.edu.ua/handle/123456789/84103
Or use following links to share this resource in social networks: Recommend this item
Title Heat transfer and simulated coronary circulation system optimization algorithms for real power loss reduction
Authors Kanagasabai, L.
ORCID
Keywords optimal reactive power
transmission loss
heat transfer
simulated coronary circulation system
Type Article
Date of Issue 2021
URI https://essuir.sumdu.edu.ua/handle/123456789/84103
Publisher Sumy State University
License Creative Commons Attribution - NonCommercial 4.0 International
Citation Kanagasabai L. (2021). Heat transfer and simulated coronary circulation system optimization algorithms for real power loss reduction. Journal of Engineering Sciences, Vol. 8(1), pp. E1–E8, doi: 10.21272/jes.2021.8(1).e1
Abstract In this paper, the heat transfer optimization (HTO) algorithm and simulated coronary circulation system (SCCS) optimization algorithm has been designed for Real power loss reduction. In the projected HTO algorithm, every agent is measured as a cooling entity and surrounded by another agent, like where heat transfer will occur. Newton’s law of cooling temperature will be updated in the proposed HTO algorithm. Each value of the object is computed through the objective function. Then the objects are arranged in increasing order concerning the objective function value. This projected algorithm time “t” is linked with iteration number, and the value of “t” for every agent is computed. Then SCCS optimization algorithm is projected to solve the optimal reactive power dispatch problem. Actions of human heart veins or coronary artery development have been imitated to design the algorithm. In the projected algorithm candidate solution is made by considering the capillaries. Then the coronary development factor (CDF) will appraise the solution, and population space has been initiated arbitrarily. Then in the whole population, the most excellent solution will be taken as stem, and it will be the minimum value of the Coronary development factor. Then the stem crown production is called the divergence phase, and the other capillaries’ growth is known as the clip phase. Based on the arteries leader’s coronary development factor (CDF), the most excellent capillary leader’s (BCL) growth will be there. With and without L-index (voltage stability), HTO and SCCS algorithm’s validity are verified in IEEE 30 bus system. Power loss minimized, voltage deviation also reduced, and voltage stability index augmented.
Appears in Collections: Journal of Engineering Sciences / Журнал інженерних наук

Views

Canada Canada
1
China China
513829480
Greece Greece
1
Hong Kong SAR China Hong Kong SAR China
521140
India India
1
Indonesia Indonesia
3126836
Iran Iran
31078178
Iraq Iraq
1
Ireland Ireland
260572
Japan Japan
1
Lithuania Lithuania
1
Mongolia Mongolia
1
South Korea South Korea
1
Turkey Turkey
68551
Ukraine Ukraine
258478164
United Kingdom United Kingdom
72389086
United States United States
-631173373
Unknown Country Unknown Country
1
Vietnam Vietnam
1921

Downloads

China China
1
Finland Finland
1
Germany Germany
-1510927312
India India
1024532110
Indonesia Indonesia
1
Iran Iran
5857
Ireland Ireland
1
Lithuania Lithuania
1
Philippines Philippines
1
Turkey Turkey
521141
Ukraine Ukraine
513829479
United Kingdom United Kingdom
1
United States United States
248580565
Vietnam Vietnam
1

Files

File Size Format Downloads
Kanagasabai_jes_1_2021.pdf 493.11 kB Adobe PDF 276541848

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.