Please use this identifier to cite or link to this item:
https://essuir.sumdu.edu.ua/handle/123456789/86378
Or use following links to share this resource in social networks:
Tweet
Recommend this item
Title | Design and Analysis of a High-Performance Capsule-Shaped 2D-Photonic Crystal Biosensor: Application in Biomedicine |
Other Titles |
Розробка та аналіз високопродуктивного капсулоподібного біосенсора на 2D фотонних кристалах: застосування в біомедицині |
Authors |
Tayoub, H.
Hocini, A. Harhouz, A. |
ORCID | |
Keywords |
фотонно-кристалічний (PhC) біосенсор компоненти крові рак чутливість добротність капсула-мікропорожнина PhC biosensor blood components cancer sensitivity quality-factor capsule-microcavity |
Type | Article |
Date of Issue | 2021 |
URI | https://essuir.sumdu.edu.ua/handle/123456789/86378 |
Publisher | Sumy State University |
License | In Copyright |
Citation | H. Tayoub, A. Hocini, et al., J. Nano- Electron. Phys. 13 No 6, 06005 (2021). DOI: https://doi.org/10.21272/jnep.13(6).06005 |
Abstract |
У статті успішно запропонований, розроблений та оцінений новий капсулоподібний біосенсор на
двовимірних фотонних кристалах (2D-PhC), який може визначати різні рідини організму та ракові
клітини для біомедичних застосувань. Для виявлення компонентів крові та ракових клітин проведено
моделювання та аналіз з використанням методу розкладання плоскої хвилі (PWE) та алгоритму кінцевих різниць у часовій області (FDTD), для яких відбираються зразки у рідкій формі та поміщуються
у капсулоподібну порожнину. Біосенсор складається з капсулоподібної порожнини, з'єднаної з двома
хвилеводами, а чутлива область має капсульну геометрію і розташована в центральній області оптичного хвилеводу. Чутливий механізм запропонованого біосенсора заснований на зміні показника заломлення аналіту. Висока чутливість 609,25 нм на одиницю показника заломлення (нм/RIU), низька
межа виявлення 3,9×10 – 6 RIU і добротність до 107 спрогнозовані для конкретного розташування сенсорної матриці в діапазоні довжин хвиль від 1,4367 до 2,0233 мкм. Ці значення демонструють потенціал біосенсора, який розглядається. Щоб переконатися у достовірності запропонованого біосенсора,
проведено порівняння результатів цієї роботи та відповідної літератури для фотонно-кристалічних
(2D-PhC) біосенсорів. In this paper, a novel capsule-shaped two-dimensional photonic crystal (2D-PhC) biosensor, which can sense different body fluids and cancer cells for biomedical applications, has been successfully proposed, designed, and evaluated. Simulation and analysis using Plane Wave Expansion (PWE) method and FiniteDifference Time-Domain (FDTD) algorithm have been done to detect blood components and cancer cells, in which samples are taken in liquid form and penetrate a capsule-shaped cavity. It consists of a capsuleshaped cavity coupled to two waveguides, and the sensing region has a capsular geometry and is positioned in the central region of the optical waveguide. The sensing mechanism of the present biosensor is based on changing the refractive index of the analyte. A high sensitivity of 609.25 nm per refractive index unit (nm/RIU), a low detection limit of 3.9 × 10 – 6 RIU and a Q-factor of up to 107 are predicted for a specific sensor-array arrangement in the wavelength range of 1.4367 to 2.0233 µm. These values demonstrate the potentiality of the proposed biosensor. To ensure the validity of the proposed biosensor, a comparison between the results of the present work and related literature for 2D-PhC biosensors has been made. |
Appears in Collections: |
Журнал нано- та електронної фізики (Journal of nano- and electronic physics) |
Views
Algeria
2001740953
Canada
1
China
-197390800
Egypt
198020
Finland
32
France
14475973
Germany
1694173411
Greece
2498
India
-938860760
Iran
14475994
Iraq
1105946447
Ireland
2755631
Kazakhstan
347340376
Lithuania
1
Mexico
1
Pakistan
1
Poland
1
Saudi Arabia
1
South Korea
1386605872
Sweden
1
Taiwan
1
Turkey
2001740952
Ukraine
1785733727
United Kingdom
2001740951
United States
-938860762
Unknown Country
-1497134425
Vietnam
2496
Downloads
Algeria
187606
Austria
1
Bangladesh
1
China
-1880744511
Colombia
1
Egypt
1
France
14475979
Germany
561296649
Ghana
1
India
161721
Indonesia
238858
Iran
1472339043
Ireland
1
Japan
172
Lithuania
1
Romania
1
Saudi Arabia
1785733724
Singapore
-1880744511
South Korea
561296648
Spain
1
Switzerland
-1880744511
Thailand
1
Ukraine
1
United Kingdom
1
United States
-938860764
Unknown Country
176
Vietnam
1
Files
File | Size | Format | Downloads |
---|---|---|---|
Tayoub_jnep_6_2021.pdf | 627.47 kB | Adobe PDF | 2109603588 |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.