Please use this identifier to cite or link to this item:
https://essuir.sumdu.edu.ua/handle/123456789/89566
Or use following links to share this resource in social networks:
Tweet
Recommend this item
Title | Determination of rSpike Protein by Specific Antibodies with Screen-Printed Carbon Electrode Modified by Electrodeposited Gold Nanostructures |
Authors |
Drobysh, M.
Liustrovaite, V. Baradoke, A. Viter, Roman Vitaliiovych Chen, C-F. Ramanavicius, A. Ramanaviciene, A. |
ORCID | |
Keywords |
COVID-19 SARS-CoV-2 virus electrochemical immunosensor differential pulse voltammetry (DPV) cyclic voltammetry (CV) electrochemical impedance spectroscopy (EIS) self-assembled monolayer (SAM) antigen–antibody complex spike protein (Spike) gold nanostructures (AuNS) |
Type | Article |
Date of Issue | 2022 |
URI | https://essuir.sumdu.edu.ua/handle/123456789/89566 |
Publisher | MDPI |
License | Creative Commons Attribution 4.0 International License |
Citation | Drobysh, M.; Liustrovaite, V.; Baradoke, A.; Viter, R.; Chen, C.-F.; Ramanavicius, A.; Ramanaviciene, A. Determination of rSpike Protein by Specific Antibodies with Screen-Printed Carbon Electrode Modified by Electrodeposited Gold Nanostructures. Biosensors 2022, 12, 593. https://doi.org/10.3390/bios12080593 |
Abstract |
In this research, we assessed the applicability of electrochemical sensing techniques for detecting specific antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike proteins in the blood serum of patient samples following coronavirus disease 2019 (COVID-19). Herein, screen-printed carbon electrodes (SPCE) with electrodeposited gold nanostructures (AuNS) were modified with L-Cysteine for further covalent immobilization of recombinant SARS-CoV-2 spike proteins (rSpike). The affinity interactions of the rSpike protein with specific antibodies against this protein (anti-rSpike) were assessed using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods. It was revealed that the SPCE electroactive surface area increased from 1.49 ± 0.02 cm2 to 1.82 ± 0.01 cm2 when AuNS were electrodeposited, and the value of the heterogeneous electron transfer rate constant (k0) changed from 6.30 × 10−5 to 14.56 × 10−5. The performance of the developed electrochemical immunosensor was evaluated by calculating the limit of detection and limit of quantification, giving values of 0.27 nM and 0.81 nM for CV and 0.14 nM and 0.42 nM for DPV. Furthermore, a specificity test was performed with a solution of antibodies against bovine serum albumin as the control aliquot, which was used to assess nonspecific binding, and this evaluation revealed that the developed rSpike-based sensor exhibits low nonspecific binding towards anti-rSpike antibodies. |
Appears in Collections: |
Наукові видання (НН МІ) |
Views

237

1

1718

1

15

240

1

16685

8343

471182

558794
Downloads

1

33128

1

33128

208348

471181

558794
Files
File | Size | Format | Downloads |
---|---|---|---|
Drobysh_et.al_Determination.pdf | 2.98 MB | Adobe PDF | 1304581 |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.