Please use this identifier to cite or link to this item: https://essuir.sumdu.edu.ua/handle/123456789/89566
Or use following links to share this resource in social networks: Recommend this item
Title Determination of rSpike Protein by Specific Antibodies with Screen-Printed Carbon Electrode Modified by Electrodeposited Gold Nanostructures
Authors Drobysh, M.
Liustrovaite, V.
Baradoke, A.
Viter, Roman Vitaliiovych
Chen, C-F.
Ramanavicius, A.
Ramanaviciene, A.
ORCID
Keywords COVID-19
SARS-CoV-2 virus
electrochemical immunosensor
differential pulse voltammetry (DPV)
cyclic voltammetry (CV)
electrochemical impedance spectroscopy (EIS)
self-assembled monolayer (SAM)
antigen–antibody complex
spike protein (Spike)
gold nanostructures (AuNS)
Type Article
Date of Issue 2022
URI https://essuir.sumdu.edu.ua/handle/123456789/89566
Publisher MDPI
License Creative Commons Attribution 4.0 International License
Citation Drobysh, M.; Liustrovaite, V.; Baradoke, A.; Viter, R.; Chen, C.-F.; Ramanavicius, A.; Ramanaviciene, A. Determination of rSpike Protein by Specific Antibodies with Screen-Printed Carbon Electrode Modified by Electrodeposited Gold Nanostructures. Biosensors 2022, 12, 593. https://doi.org/10.3390/bios12080593
Abstract In this research, we assessed the applicability of electrochemical sensing techniques for detecting specific antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike proteins in the blood serum of patient samples following coronavirus disease 2019 (COVID-19). Herein, screen-printed carbon electrodes (SPCE) with electrodeposited gold nanostructures (AuNS) were modified with L-Cysteine for further covalent immobilization of recombinant SARS-CoV-2 spike proteins (rSpike). The affinity interactions of the rSpike protein with specific antibodies against this protein (anti-rSpike) were assessed using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods. It was revealed that the SPCE electroactive surface area increased from 1.49 ± 0.02 cm2 to 1.82 ± 0.01 cm2 when AuNS were electrodeposited, and the value of the heterogeneous electron transfer rate constant (k0) changed from 6.30 × 10−5 to 14.56 × 10−5. The performance of the developed electrochemical immunosensor was evaluated by calculating the limit of detection and limit of quantification, giving values of 0.27 nM and 0.81 nM for CV and 0.14 nM and 0.42 nM for DPV. Furthermore, a specificity test was performed with a solution of antibodies against bovine serum albumin as the control aliquot, which was used to assess nonspecific binding, and this evaluation revealed that the developed rSpike-based sensor exhibits low nonspecific binding towards anti-rSpike antibodies.
Appears in Collections: Наукові видання (НН МІ)

Views

Austria Austria
237
China China
1
Ireland Ireland
1718
Japan Japan
1
Norway Norway
15
Russia Russia
240
Singapore Singapore
1
Ukraine Ukraine
16685
United Kingdom United Kingdom
8343
United States United States
471182
Unknown Country Unknown Country
60370

Downloads

China China
1
Germany Germany
33128
Romania Romania
1
Ukraine Ukraine
33128
United Arab Emirates United Arab Emirates
208348
United States United States
471181
Unknown Country Unknown Country
558794

Files

File Size Format Downloads
Drobysh_et.al_Determination.pdf 2.98 MB Adobe PDF 1304581

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.