Please use this identifier to cite or link to this item: https://essuir.sumdu.edu.ua/handle/123456789/93027
Or use following links to share this resource in social networks: Recommend this item
Title Study of Cobalt Nanoparticle Modified Gold Electrode
Other Titles Дослідження електрода із золота, модифікованого наночастинками кобальту
Authors Fanani, N.
Murwani, I.K.
Kurniawan, F.
ORCID
Keywords кобальтовий електрод
фосфати
потенціометрія
циклічна вольт-амперометрія
сенсор
cobalt electrode
phosphates
potentiometry
cyclic voltammetry
sensor
Type Article
Date of Issue 2023
URI https://essuir.sumdu.edu.ua/handle/123456789/93027
Publisher Sumy State University
License In Copyright
Citation Nurull Fanani, Irmina Kris Murwani, Fredy Kurniawan[footnoteRef:], J. Nano- Electron. Phys. 15 No 4, 04025 (2023) DOI: https://doi.org/10.21272/jnep.15(4).04025
Abstract Було проведено виявлення фосфатів за допомогою золотого електрода, модифікованого наночастинками кобальту. Наночастинки оксиду кобальту отримували змішуванням розчину хлориду кобальту з 10 % гліцерином і додаванням розчину гідроксиду амонію при перемішуванні протягом 2 годин при 50 °C. Потім розчин залишали на 12 годин. Отриманий осад відфільтрували і відпалили при 700°C протягом години. Отримані наночастинки кобальту змішали з нафіоном, потім прикріпили до золотого дроту для формування модифікованого електрода з наночастинок кобальту. Ефективність цього електрода перевіряли у порівнянні з розчином фосфату за допомогою триелектродної системи Autolab Metrohm типу AUT 84948. Вимірювання проводили шляхом занурення модифікованого кобальтового золотого електрода, підключеного до триелектродної системи Metrohm Autolab. Усі вимірювання фосфатів проводили в буферних розчинах KHP і KCl. Вольт-амперограмми KHP не показали піків анодного та катодного струмів, але у фосфатному розчині (10 ppm NaH2PO4) показали піки катодних струмів при потенціалі – 1,009 В. Це вказувало на чутливість електрода до розчинів фосфатних іонів. Катодний струм зростає зі збільшенням концентрації фосфату. Межа виявлення вимірювання становить 0,47 ppm.
Phosphate detection using Cobalt nanoparticle modified gold electrode has been carried out. Cobalt oxide nanoparticles were produced by mixing a solution of cobalt chloride with 10 % glycerol and adding Ammonium hydroxide solution with stirring for 2 hours at 50 °C using a magnetic stirrer. The solution was then allowed to stand for 12 hours. The precipitate obtained was filtered and calcined at 700 °C for one hour. The obtained cobalt nanoparticles are mixed with nafion, then attached to a gold wire to form a modified cobalt nanoparticle electrode. The performance of this electrode was tested against a phosphate solution using a three-electrode system of the Autolab Metrohm type AUT 84948. Measurements were made by immersing a modified cobalt gold electrode connected to the Metrohm Autolab three-electrode system. All phosphate measurements were carried out in KHP and KCl buffer solutions. Voltammograms of KHP did not show peaks of anodic and cathodic currents but in phosphate solution (10 ppm NaH2PO4) showed peaks of cathodic currents at a potential of – 1.009 V. This indicated that the electrode was sensitive to phosphate ion solutions. The cathodic current increases with the phosphate concentration. The measurement detection limit is 0.47 ppm.
Appears in Collections: Журнал нано- та електронної фізики (Journal of nano- and electronic physics)

Views

Australia Australia
1
Canada Canada
1
China China
1560
Germany Germany
1
Indonesia Indonesia
7275
Poland Poland
1
Singapore Singapore
1
Ukraine Ukraine
1
United Kingdom United Kingdom
12
United States United States
23407
Unknown Country Unknown Country
7273

Downloads

China China
23403
Finland Finland
1
Indonesia Indonesia
23406
Ukraine Ukraine
1
United States United States
7277
Unknown Country Unknown Country
251

Files

File Size Format Downloads
Nurull_Fanani_jnep_4_2023.pdf 374.33 kB Adobe PDF 54339

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.