An increase in the energy efficiency of vortex micro HPP with a flexible outlet siphon by self-adjustment of flows in the pressure chamber

dc.contributor.authorZivzivadze, O.
dc.contributor.authorGeguchadze, A.
dc.contributor.authorZivzivadze, B.
dc.contributor.authorDzadzamia, D.
dc.contributor.authorKuparadze, A.
dc.contributor.authorSulakvelidze, N.
dc.date.accessioned2024-10-29T07:53:46Z
dc.date.available2024-10-29T07:53:46Z
dc.date.issued2024
dc.description.abstractThe article aims to increase the energy efficiency of the vortex micro-power plant, which would be achieved due to its compatibility with the terrain. In particular, the inlet channel connected to the water intake of the pressure chamber and the water collector placed in the upper pool by transverse joints, and the flexible siphon connected by vertical and horizontal joints to the diffuser of the same chamber with a telescopic end. The boundary conditions were selected with parameters such as the water flow acceleration according to the river bed’s slope angle and the inclination angle of the upstream channel near the vertical pressure cone chamber. The level difference between the upper and lower pools was adjusted. Inside the pressure chamber, the inclined guides of the small wings were hinged to its wall and were adjusted by ballasts. The reactive forces generated by the upward reflection of the incoming flow from the surfaces on the inclined small guide wings of the pressure chamber were a factor in curbing the said flow (compensating for the insufficient volume flow) and ensuring the continuity of the water supply to the turbine in shallow water. The mentioned circumstances allowed for improving the synchronization of incoming and outgoing flows. As a result of the above improvements, an increase in the energy efficiency (i.e., annual electricity generation) of 15–20 % was achieved.en_US
dc.identifier.citationZivzivadze O., Geguchadze A., Zivzivadze B., Dzadzamia D., Kuparadze A., Sulakvelidze N. (2024). An increase in the energy efficiency of vortex micro HPP with a flexible outlet siphon by self-adjustment of flows in the pressure chamber. Journal of Engineering Sciences (Ukraine), Vol. 11(2), pp. G17–G23. https://doi.org/10.21272/jes.2024.11(2).g3en_US
dc.identifier.urihttps://essuir.sumdu.edu.ua/handle/123456789/97172
dc.language.isoenen_US
dc.publisherSumy State Universityen_US
dc.rights.uriCC BY-NC 4.0en_US
dc.subjectlow head turbineen_US
dc.subjectenergy efficiencyen_US
dc.subjectascending channelen_US
dc.subjectsmall guide wingsen_US
dc.subjectinflowen_US
dc.subjectoutflowen_US
dc.titleAn increase in the energy efficiency of vortex micro HPP with a flexible outlet siphon by self-adjustment of flows in the pressure chamberen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Zivzivadze_jes_2_2024.pdf
Size:
655.68 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
3.96 KB
Format:
Item-specific license agreed upon to submission
Description: