Видання зареєстровані авторами шляхом самоархівування
Permanent URI for this communityhttps://devessuir.sumdu.edu.ua/handle/123456789/1
Browse
8 results
Search Results
Item Effects of the sources of calcium and phosphorus on the structural and functional properties of ceramic coatings on titanium dental implants produced by plasma electrolytic oxidation(Elsevier, 2021) Кириленко, Сергій Дмитрович; Kyrylenko, Serhii Dmytrovych; Warchoł, F.; Олешко, Олександр Миколайович; Oleshko, Oleksandr Mykolaiovych; Гусак, Євгенія Володимирівна; Husak, Yevheniia Volodymyrivna; Kazek-Kęsik, A.; Корнiєнко, Вiкторiя Володимирiвна; Korniienko, Viktoriia Volodymyrivna; Дейнека, Володимир Миколайович; Deineka, Volodymyr Mykolaiovych; Sowa, M.; Maciej, A.; Michalska, J.; Jakóbik-Kolon, A.; Matuła, I.; Basiaga, M.; Голубнича, Вікторія Миколаївна; Holubnycha, Viktoriia Mykolaivna; Stolarczyk, A.; Pisarek, M.; Mishchenko, O.; Погорєлов, Максим Володимирович; Pohorielov, Maksym Volodymyrovych; Simka, W.Plasma Electrolytic Oxidation (PEO) is as a promising technique to modify metal surfaces by application of oxide ceramic coatings with appropriate physical, chemical and biological characteristics. Therefore, objective of this research was to find the simplest settings, yet able to produce relevant bioactive implant surfaces layers on Ti implants by means of PEO. We show that an electrolyte containing potassium dihydrogen phosphate as a source of P and either calcium hydroxide or calcium formate as a source of Ca in combination with a chelating agent, ethylenediamine tetraacetic acid (EDTA), is suitable for PEO to deliver coatings with desired properties. We determined surface morphology, roughness, wettability, chemical and phase composition of titanium after the PEO process. To investigate biocompatibility and bacterial properties of the PEO oxide coatings we used microbial and cell culture tests. The electrolyte based on Ca(OH)2 and EDTA promotes active crystallization of apatites after PEO processing of the Ti implants. The PEO layers can increase electrochemical corrosion resistance. The PEO can be potentially used for development of bioactive surfaces with increased support of eukaryotic cells while inhibiting attachment and growth of bacteria without use of antibacterial agents.Item Synthetic Calcium–Phosphate Materials for Bone Grafting(MDPI Open Access Publishing, 2023) Mishchenko, O.; Яновська, Ганна Олександрівна; Yanovska, Hanna Oleksandrivna; Kosinov, O.; Maksymov, D.; Москаленко, Роман Андрійович; Moskalenko, Roman Andriiovych; Ramanavicius, A.; Погорєлов, Максим Володимирович; Pohorielov, Maksym VolodymyrovychSynthetic bone grafting materials play a significant role in various medical applications involving bone regeneration and repair. Their ability to mimic the properties of natural bone and promote the healing process has contributed to their growing relevance. While calcium–phosphates and their composites with various polymers and biopolymers are widely used in clinical and experimental research, the diverse range of available polymer-based materials poses challenges in selecting the most suitable grafts for successful bone repair. This review aims to address the fundamental issues of bone biology and regeneration while providing a clear perspective on the principles guiding the development of synthetic materials. In this study, we delve into the basic principles underlying the creation of synthetic bone composites and explore the mechanisms of formation for biologically important complexes and structures associated with the various constituent parts of these materials. Additionally, we offer comprehensive information on the application of biologically active substances to enhance the properties and bioactivity of synthetic bone grafting materials. By presenting these insights, our review enables a deeper understanding of the regeneration processes facilitated by the application of synthetic bone composites.Item From Synthesis to Clinical Trial: Novel Bioinductive Calcium Deficient HA/β-TCP Bone Grafting Nanomaterial(International and interdisciplinary scholarly open access journal, 2023) Mishchenko, O.; Яновська, Ганна Олександрівна; Yanovska, Hanna Oleksandrivna; Sulaieva, O.; Москаленко, Роман Андрійович; Moskalenko, Roman Andriiovych; Пернаков, Микола Станіславович; Pernakov, Mykola Stanislavovych; Гусак, Євгенія Володимирівна; Husak, Yevheniia Volodymyrivna; Корнiєнко, Вiкторiя Володимирiвна; Korniienko, Viktoriia Volodymyrivna; Дейнека, Володимир Миколайович; Deineka, Volodymyr Mykolaiovych; Kosinov, O.; Varakuta, O.; Ramanavicius, S.; Varzhapetjan, S.; Ramanaviciene, A.; Krumina, D.; Knipše, G.; Ramanavicius, A.; Погорєлов, Максим Володимирович; Pohorielov, Maksym VolodymyrovychЗбільшення верхньощелепної пазухи є широко використовуваною процедурою для встановлення зубних імплантатів. Однак використання натуральних і синтетичних матеріалів у цій процедурі призвело до післяопераційних ускладнень від 12% до 38%. Щоб вирішити цю проблему, ми розробили новий наноматеріал для трансплантації кісткової тканини HA/β-TCP з дефіцитом кальцію, використовуючи метод двоетапного синтезу з відповідними структурними та хімічними параметрами для застосування підтяжки синусів. Ми продемонстрували, що наш наноматеріал демонструє високу біосумісність, посилює клітинну проліферацію та стимулює експресію колагену. Крім того, деградація β-TCP у нашому наноматеріалі сприяє утворенню тромбів, що підтримує агрегацію клітин і ріст нової кістки. У клінічному дослідженні, яке включало вісім випадків, ми спостерігали формування компактної кісткової тканини через 8 місяців після операції, що дозволило успішно встановити зубні імплантати без будь-яких ранніх післяопераційних ускладнень. Наші результати свідчать про те, що наш новий наноматеріал для пересадки кісткової тканини має потенціал для підвищення ефективності процедур збільшення гайморової пазухи.Item Bioactivity Performance of Pure Mg after Plasma Electrolytic Oxidation in Silicate-Based Solutions(MDPI, 2021) Гусак, Євгенія Володимирівна; Гусак, Евгения Владимировна; Husak, Yevheniia Volodymyrivna; Michalska, J.; Олешко, Олександр Миколайович; Олешко, Александр Николаевич; Oleshko, Oleksandr Mykolaiovych; Корнiєнко, Вiкторiя Володимирiвна; Корниенко, Виктория Владимировна; Korniienko, Viktoriia Volodymyrivna; Grundsteins, K.; Дригваль, Богдан Олександрович; Дрыгваль, Богдан Александрович; Dryhval, Bohdan Oleksandrovych; Altundal, S.; Mishchenko, O.; Вітер, Роман Віталійович; Ветер, Роман Витальевич; Viter, Roman Vitaliiovych; Simka, W.The biodegradable metals, including magnesium (Mg), are a convenient alternative to permanent metals but fast uncontrolled corrosion limited wide clinical application. Formation of a barrier coating on Mg alloys could be a successful strategy for the production of a stable external layer that prevents fast corrosion. Our research was aimed to develop an Mg stable oxide coating using plasma electrolytic oxidation (PEO) in silicate-based solutions. 99.9% pure Mg alloy was anodized in electrolytes contained mixtures of sodium silicate and sodium fluoride, calcium hydroxide and sodium hydroxide. Scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), contact angle (CA), Photoluminescence analysis and immersion tests were performed to assess structural and long-term corrosion properties of the new coating. Biocompatibility and antibacterial potential of the new coating were evaluated using U2OS cell culture and the grampositive Staphylococcus aureus (S. aureus, strain B 918). PEO provided the formation of a porous oxide layer with relatively high roughness. It was shown that Ca(OH)2 was a crucial compound for oxidation and surface modification of Mg implants, treated with the PEO method. The addition of Ca2+ ions resulted in more intense oxidation of the Mg surface and growth of the oxide layer with a higher active surface area. Cell culture experiments demonstrated appropriate cell adhesion to all investigated coatings with a significantly better proliferation rate for the samples treated in Ca(OH)2 - containing electrolyte. In contrast, NaOH-based electrolyte provided more relevant antibacterial effects but did not support cell proliferation. In conclusion, it should be noted that PEO of Mg alloy in silicate baths containing Ca(OH)2 provided the formation of stable biocompatible oxide coatings that could be used in the development of commercial degradable implantsItem Fast LIPSS based texturing process of dental implants with complex geometries(Elsevier, 2020) Orazi, L.; Pelaccia, R.; Mishchenko, O.; Reggiani, B.; Погорєлов, Максим Володимирович; Погорелов, Максим Владимирович; Pohorielov, Maksym VolodymyrovychIn the present work, the generation of Laser Induced Periodic Surface Structures (LIPSS) by using femtosecond laser source is investigated in the surface texturing of Ti grade 5 dental implants. The proposed procedure permits a fast treatment of dental implants characterized by complex shape through the combined and synchronous use of a galvo scanner and of workpiece movements. The obtained surface micro- and nanostructures are characterized from a morphological point of view while in-vitro essays are performed to evaluate cellular proliferation. The results indicate the effectiveness of the LIPSS as a method to increase cell viability and the efficiency of the proposed procedure to treat complex geometries as dental implants.Item Biocompatibility and Antibacterial Properties of ZnO-Incorporated Anodic Oxide Coatings on TiZrNb Alloy(MDPI, 2020) Олешко, Олександр Миколайович; Олешко, Александр Николаевич; Oleshko, Oleksandr Mykolaiovych; Гусак, Євгенія Володимирівна; Гусак, Евгения Владимировна; Husak, Yevheniia Volodymyrivna; Корнiєнко, Вiкторiя Володимирiвна; Корниенко, Виктория Владимировна; Korniienko, Viktoriia Volodymyrivna; Пшеничний, Роман Миколайович; Пшеничный, Роман Николаевич; Pshenychnyi, Roman Mykolaiovych; Варава, Юлія Валентинівна; Варава, Юлия Валентиновна; Varava, Yuliia Valentynivna; Калінкевич, Оксана Володимирівна; Калинкевич, Оксана Владимировна; Kalinkevych, Oksana Vladymyrovna; Pisarek, M.; Grundsteins, K.; Pogorielova, O.; Mishchenko, O.; Simka, W.; Вітер, Роман Віталійович; Ветер, Роман Витальевич; Viter, Roman Vitaliiovych; Погорєлов, Максим Володимирович; Погорелов, Максим Владимирович; Pohorielov, Maksym VolodymyrovychIn a present paper, we demonstrate novel approach to form ceramic coatings with incorporated ZnO nanoparticles (NPs) on low modulus TiZrNb alloy with enhanced biocompatibility and antibacterial parameters. Plasma Electrolytic Oxidation (PEO) was used to integrate ZnO nanoparticles (average size 12–27 nm), mixed with Ca(H2PO2)2 aqueous solution into low modulus TiZrNb alloy surface. The TiZrNb alloys with integrated ZnO NPs successfully showed higher surface porosity and contact angle. XPS investigations showed presence of Ca ions and absence of phosphate ions in the PEO modified layer, what explains higher values of contact angle. Cell culture experiment (U2OS type) confirmed that the surface of as formed oxide-ZnO NPs demonstrated hydrophobic properties, what can affect primary cell attachment. Further investigations showed that Ca ions in the PEO coating stimulated proliferative activity of attached cells, resulting in competitive adhesion between cells and bacteria in clinical situation. Thus, high contact angle and integrated ZnO NPs prevent bacterial adhesion and considerably enhance the antibacterial property of TiZrNb alloys. A new anodic oxide coating with ZnO NPs could be successfully used for modification of low modulus alloys to decrease post-implantation complications.Item Formation of a Bacteriostatic Surface on ZrNb Alloy via Anodization in a Solution Containing Cu Nanoparticles(MDPI, 2020) Корнiєнко, Вiкторiя Володимирiвна; Корниенко, Виктория Владимировна; Korniienko, Viktoriia Volodymyrivna; Олешко, Олександр Миколайович; Олешко, Александр Николаевич; Oleshko, Oleksandr Mykolaiovych; Гусак, Євгенія Володимирівна; Гусак, Евгения Владимировна; Husak, Yevheniia Volodymyrivna; Дейнека, Володимир Миколайович; Дейнека, Владимир Николаевич; Deineka, Volodymyr Mykolaiovych; Голубнича, Вікторія Миколаївна; Голубничая, Виктория Николаевна; Holubnycha, Viktoriia Mykolaivna; Mishchenko, O.; Kazek-Kęsik, A.; Jakobik-Kolon, A.; Пшеничний, Роман Миколайович; Пшеничный, Роман Николаевич; Pshenychnyi, Roman Mykolaiovych; Leśniak-Ziółkowska, K.; Kalinkevich, O.; Kalinkevich, A.; Pisarek, M.; Simka, W.; Погорєлов, Максим Володимирович; Погорелов, Максим Владимирович; Pohorielov, Maksym VolodymyrovychHigh strength, excellent corrosion resistance, high biocompatibility, osseointegration ability, and low bacteria adhesion are critical properties of metal implants. Additionally, the implant surface plays a critical role as the cell and bacteria host, and the development of a simultaneously antibacterial and biocompatible implant is still a crucial challenge. Copper nanoparticles (CuNPs) could be a promising alternative to silver in antibacterial surface engineering due to low cell toxicity. In our study, we assessed the biocompatibility and antibacterial properties of a PEO (plasma electrolytic oxidation) coating incorporated with CuNPs (Cu nanoparticles). The structural and chemical parameters of the CuNP and PEO coating were studied with TEM/SEM (Transmission Electron Microscopy/Scanning Electron Microscopy), EDX (Energy-Dispersive X-ray Dpectroscopy), and XRD (X-ray Diffraction) methods. Cell toxicity and bacteria adhesion tests were used to prove the surface safety and antibacterial properties. We can conclude that PEO on a ZrNb alloy in Ca–P solution with CuNPs formed a stable ceramic layer incorporated with Cu nanoparticles. The new surface provided better osteoblast adhesion in all time-points compared with the nontreated metal and showed medium grade antibacterial activities. PEO at 450 V provided better antibacterial properties that are recommended for further investigation.Item New Zr-Ti-Nb Alloy for Medical Application: Development, Chemical and Mechanical Properties, and Biocompatibility(MDPI, 2020) Mishchenko, O.; Ovchynnykov, O.; Kapustian, O.; Погорєлов, Максим Володимирович; Погорелов, Максим Владимирович; Pohorielov, Maksym VolodymyrovychThe concept of mechanical biocompatibilities is considered an important factor for orthopedics and dental implants. The high Young modulus of traditional Ti-based alloys can lead to stress-shielding syndrome and late postoperative complications. The development of new Al- and V-free Ti alloys with a low elastic modulus is a critical task for implantology. Despite the relatively low Young modulus and appropriate biological response of metastable beta-Ti alloys, their production requires complex metallurgical solutions and a high final cost that limit commercial application. The current research aimed to develop a Zr-Ti-Nb system with a low Young modulus suitable for biomedical application, including orthopedics and dental implantology. Two different charges were used for new alloy production with melting in a vacuum-arc furnace VDP-1 under atmospheric control (argon + helium) with a non-consumable tungsten electrode and a water-cooled copper crystallizer. Post-treatment included a forging-rolling process to produce a bar suitable for implant production. SEM with EDX and the mechanical parameters of the new alloy were evaluated, and a cell culture experiment provided a biocompatibility assessment. The chemical composition of the new alloy can be represented as 59.57-19.02-21.41 mass% of Zr-Ti-Nb. The mechanical properties are characterized by an extremely low Young modulus—27,27 GPa for the alloy and 34.85 GPa for the bar. The different master alloys used for Zr-Ti-Nb production did not affect the chemical compound and mechanical parameters so it was possible to use affordable raw materials to decrease the final price of the new product. The cell culture experiment demonstrated a full biocompatibility, indicating that this new alloy can be used for dental and orthopedics implant production.