Please use this identifier to cite or link to this item: http://essuir.sumdu.edu.ua/handle/123456789/73544
Or use following links to share this resource in social networks: Recommend this item
Title Numerical Study of the Effect of Changing Tube Pitches on Heat and Flow Characteristics from Tube Bundles in Cross Flow
Other Titles Числове дослідження впливу кроку труб на теплові та гідравлічні характеристики трубних пучків у поперечному потоці
Authors Petinrin, M.O.
Towoju, O.A.
Ajiboye, S.A.
Zebulun, O.E.
Keywords поперечний потік
змінний крок
трубний пучок
теплопередача
теплотехнічні характеристики
cross flow
varying pitch
tube bundle
heat transfer
thermal-hydraulic performance
Type Article
Date of Issue 2019
URI http://essuir.sumdu.edu.ua/handle/123456789/73544
Publisher Sumy State University
License
Citation Numerical Study of the Effect of Changing Tube Pitches on Heat and Flow Characteristics from Tube Bundles in Cross Flow [Текст] / M.O. Petinrin, O.A. Towoju, S.A. Ajiboye, O.E. Zebulun // Журнал інженерних наук. - 2019. - Т. 6, № 2. - С. Е1-Е10. - DOI: 10.21272/jes.2019.6(2).e1
Abstract У різних теплообмінних апаратах трубні пучки застосовуються для передачі теплової енергії між рідинам. Проте, міжтрубний простів будь-якого трубного пучка є визначальним фактором його теплових і гідравлічних характеристик. У цій роботі чисельно проаналізовано вплив зміни поперечного і поздовжнього кроків у нижній частині трубного пучка на характеристики потоку і теплопередачі. Досліджено сім варіантів розташування труб зі змінним кроком для чисел Рейнольдса у діапазоні від 7 381 до 22 214. Аналіз проводився із застосуванням моделі турбулентності k-ε із заданими граничними умовами із комп’ютерною реалізацією методом скінченних об’ємів у COMSOL Multiphysics. Отримані результати добре узгоджуються з існуючими залежностями. Трубні пучки зі зменшеною відстанню дають кращу теплопередачу. Збільшення ж відстані призводить до зменшення гідравлінчного коефіцієнта тертя.
Tube bundles are found in various heat transfer equipment for thermal energy transfer between fluids. However, the inter-spatial arrangement of the tubes of any tube bundle is a determining factor for its thermal and hydraulic performance. In this paper, the effect of varying the transverse and longitudinal pitches downstream staggered circular tube bundle on the heat transfer and flow characteristic was numerically analyzed. Seven variations of tube arrangements were studied by changing the tube pitches within a Reynolds number range of 7 381 to 22 214. The analyses were carried out using the k-ε equation model imposed with the realizability constraint and were solved with finite volume CFD code, COMSOL Multiphysics. The results obtained were found to be in good agreement with existing correlations. The tube bundles with decreasing pitches demonstrated better heat transfer performance while those with increasing pitches exhibited a lower friction factor. Thus, the best thermal-hydraulic performance was obtained from increasing pitch arrangements.
Appears in Collections: Журнал інженерних наук

Views

Canada Canada
1
China China
52852
Germany Germany
1
Hong Kong SAR China Hong Kong SAR China
1
India India
1576
Iraq Iraq
1
Japan Japan
52862
Lithuania Lithuania
1
Netherlands Netherlands
5917
South Korea South Korea
400
Ukraine Ukraine
365
United Kingdom United Kingdom
193281
United States United States
52858
Unknown Country Unknown Country
17

Downloads

Algeria Algeria
52851
Austria Austria
5924
Brazil Brazil
52853
China China
398
Germany Germany
1
India India
193280
Iraq Iraq
193277
Japan Japan
52861
Kuwait Kuwait
52849
Morocco Morocco
1
South Africa South Africa
1
Turkey Turkey
52854
Ukraine Ukraine
364
United Kingdom United Kingdom
1
United States United States
52857
Unknown Country Unknown Country
44

Files

File Size Format Downloads
Petinrin_JES_2019_02.pdf 1,71 MB Adobe PDF 710416

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.