Title | The analysis of the performance of a sewage pump in terms of the wear of hydraulic components |
Authors |
Moloshnyi, Oleksandr Mykolaiovych
Szulc, P. Moliński, G. Sapozhnikov, Serhii Viacheslavovych Antonenko, Serhii Serhiiovych ![]() |
ORCID |
http://orcid.org/0009-0002-7490-2691 |
Keywords |
sewage pump hydraulic components wastewater |
Type | Article |
Date of Issue | 2021 |
URI | https://essuir.sumdu.edu.ua/handle/123456789/99166 |
Publisher | IOP Publishing Ltd |
License | Creative Commons Attribution 4.0 International License |
Citation | O Moloshnyi et al 2021 J. Phys.: Conf. Ser. 1741 012015. |
Abstract |
The paper presents the comparison of the performance of the three-blade centrifugal
pump operating in sewage water in the function of time. Two conditions of the analysed pump
were investigated: a new one and one after a long period of utilization. The main objects of
research were the impeller, due to its enormous wear, and the L–shape wear ring. Three
dimensional optical scanning was applied to reflect the real geometrical parameters of the
analysed pump. The investigations were conducted by means of numerical simulations and a
real test. The achieved results indicate the impact of the wear on the performance curves of