The analysis of the performance of a sewage pump in terms of the wear of hydraulic components
No Thumbnail Available
Date
2021
Journal Title
Journal ISSN
Volume Title
Publisher
IOP Publishing Ltd
Article
Date of Defense
Scientific Director
Speciality
Date of Presentation
Abstract
The paper presents the comparison of the performance of the three-blade centrifugal
pump operating in sewage water in the function of time. Two conditions of the analysed pump
were investigated: a new one and one after a long period of utilization. The main objects of
research were the impeller, due to its enormous wear, and the L–shape wear ring. Three
dimensional optical scanning was applied to reflect the real geometrical parameters of the
analysed pump. The investigations were conducted by means of numerical simulations and a
real test. The achieved results indicate the impact of the wear on the performance curves of
middle specific speed sewage pump.