Please use this identifier to cite or link to this item: https://essuir.sumdu.edu.ua/handle/123456789/86240
Or use following links to share this resource in social networks: Recommend this item
Title Medical and Economic Analysis of the Choice of Therapeutic Plasmapheresis Method to Optimize the Transfusion Care Quality
Authors Liubchak, Vladyslav Viktorovych  
Khomenko, Liliia Mykolaivna  
Kovalishyn, Mykhailo Petrovych
Ilina, Viktoriia Valeriivna  
Smiianov, Vladyslav Anatoliiovych  
Sikora, Volodymyr Vitaliiovych  
Babar, Tetiana Volodymyrivna  
ORCID http://orcid.org/0000-0003-0352-4355
http://orcid.org/0000-0001-5690-1105
http://orcid.org/0000-0002-3972-4327
http://orcid.org/0000-0001-8164-9706
http://orcid.org/0000-0003-4021-2334
http://orcid.org/0000-0002-5689-2429
Keywords automatic plasmapheresis
manual plasmapheresis
membrane plasmapheresis
centrifugal plasmapheresis
economic effect
автоматичний плазмаферез
ручний плазмаферез
мембранний плазмаферез
центрифужний плазмаферез
економічний ефект
автоматический плазмаферез
ручной плазмаферез
мембранный плазмаферез
центрифужный плазмаферез
экономический эффект
Type Article
Date of Issue 2021
URI https://essuir.sumdu.edu.ua/handle/123456789/86240
Publisher ALUNA Publishing
License Copyright not evaluated
Citation Liubchak V.V., Khomenko L.M., Kovalishyn M.P., Ilyina V.V., SmiianovV.A., Sikora V.V., Babar T.V. (2021). Medical and Economic Analysis of the Choice of Therapeutic Plasmapheresis Method to Optimize the Transfusion Care Quality. Wiadomości Lekarskie. 74(10). 2466-2470. DOI: 10.36740/WLek202110119
Abstract Мета: Аналіз медико-економічних аспектів ручного та різних видів автоматичного плазмаферезу (ручного, автоматичного центрифужного, автоматичного мембранного, плазмаферезу з плазмотерапією та змішаного), що використовуються в лікувальних цілях. Матеріали та методи: Використовували Baxter Auto-C, Haemonetics PCS2, Haemophenics, антикоагулянт і фізіологічний розчин Baxter CPDA, голки Baxter 16GA. Загальний білок досліджували біуретовим методом, гемоглобін — методом Саллі, загальний білірубін — колориметричним фотометричним методом, фрагменти клітин — методом мікроскопії камери Горяєва; комфорт пацієнта – за 10-бальною шкалою. У дослідженні брали участь здорові донори крові. Ручний плазмаферез виконано 31 особі, автоматичний плазмаферез з відцентровою технологією – 36 особам, за мембранною технологією – 21 особа, змішана технологія – 36 особам. Результати: Проведено аналіз впливу різних технологій на гематологічні, психологічні та медико-економічні показники. Нативний гемоглобін був відсутній у крові та в кінцевій плазмі за всіма технологіями. Індекс білірубіну був у межах норми. Фрагментів клітин не було. Доведено відсутність суттєвих відмінностей у різних технологіях за гематологічними показниками. Встановлено нижчий рівень комфорту пацієнта за допомогою ручного плазмаферезу. Висновок: Всі технології лікувального плазмаферезу однаково впливають на гематологічні показники крові пацієнта і не мають негативного впливу на організм за такими показниками: гемоліз, наявність уламків клітин, дискомфорт пацієнта та цитратні реакції під час стандартної процедури забору проб 800. мл плазми. Найбільш ефективними за медико-економічними параметрами є плазмаферезні апарати з відцентровою технологією.
The aim: To analyze the medical and economic aspects of the manual and different types of automatic plasmapheresis (manual, automatic centrifugal, automatic membrane, plasmapheresis with plasma therapy and mixed) used for therapeutic purposes. Materials and methods: The Baxter Auto-C, Haemonetics PCS2, Haemophenics, Baxter CPDA anticoagulant and saline, Baxter 16GA needles were used. Total protein was examined by the biuret method, hemoglobin by the Sally method, total bilirubin by the colorimetric photometric method, cell fragments by the Goryaev camera microscopy method; patient comfort – with a 10-point scale. Healthy blood donors participated in the study. Manual plasmapheresis was performed in 31 people, automatic plasmapheresis with centrifugal technology – 36 people, with membrane technology – 21 people, mixed technology – 36 people. Results: An analysis of the different technologies impact on hematological, psychological and medical and economic indicators was performed. Native hemoglobin was absent in the bloodstream and in the final plasma with all technologies. Bilirubin index was within normal limits. There were no cell fragments. It was proved the absence of significant differences in various technologies on hematological parameters. The lower level of patient comfort by manual plasmapheresis was established. Conclusion: All therapeutic plasmapheresis technologies have the same effect on the patient’s blood hematological parameters and did not have a negative impact on the body by the indicators: hemolysis, the presence of cell fragments, patient discomfort and citrate reactions during the standard procedure of sampling 800 ml of plasma. The most effective are plasmapheresis machines with centrifugal technology by medical and economic parametres.
Appears in Collections: Наукові видання (ННІ БіЕМ)

Views

China China
14582
France France
-1310014775
Germany Germany
1611363306
Greece Greece
76935
Guernsey Guernsey
1
Iran Iran
141698
Ireland Ireland
32929517
Kazakhstan Kazakhstan
1
Lithuania Lithuania
1
Malaysia Malaysia
1
Netherlands Netherlands
141295
North Macedonia North Macedonia
1
Singapore Singapore
1
Sweden Sweden
1
Ukraine Ukraine
-141174778
United Kingdom United Kingdom
1995003862
United States United States
-141174777
Unknown Country Unknown Country
51289
Vietnam Vietnam
76937

Downloads

Canada Canada
1611363308
Chile Chile
1
China China
1674930458
Egypt Egypt
1
France France
2039683567
Germany Germany
-654929744
Hong Kong SAR China Hong Kong SAR China
1
Hungary Hungary
1
India India
32929518
Indonesia Indonesia
1674930459
Iran Iran
1
Ireland Ireland
65859030
Israel Israel
1
Japan Japan
1
Lithuania Lithuania
24096421
Netherlands Netherlands
74199
Singapore Singapore
667355697
South Korea South Korea
1
Turkey Turkey
1
Ukraine Ukraine
2039683568
United Kingdom United Kingdom
65859033
United States United States
-141174780
Uzbekistan Uzbekistan
1995003875
Vietnam Vietnam
1

Files

File Size Format Downloads
Liubchak_economic effect.pdf 118,35 kB Adobe PDF -1789237269

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.