Please use this identifier to cite or link to this item:
https://essuir.sumdu.edu.ua/handle/123456789/91074
Or use following links to share this resource in social networks:
Tweet
Recommend this item
Title | High-Performance Two-Dimensional Photonic Crystal Biosensor to Diagnose Malaria Infected RBCs |
Other Titles |
Високоефективний двовимірний фотонно-кристалічний біосенсор для діагностики еритроцитів, інфікованих малярією |
Authors |
Tayoub, H.
Hocini, A. Harhouz, A. |
ORCID | |
Keywords |
фотонний кристал кільцеподібна порожнина біосенсор малярія чутливість добротність photonic crystal ring-shaped cavity biosensor malaria sensitivity quality factor |
Type | Article |
Date of Issue | 2023 |
URI | https://essuir.sumdu.edu.ua/handle/123456789/91074 |
Publisher | Sumy State University |
License | In Copyright |
Citation | H. Tayoub, A. Hocini, et al., J. Nano- Electron. Phys. 15 No 1, 01008 (2023) DOI: https://doi.org/10.21272/jnep.15(1).01008 |
Abstract |
У статті запропоновано двовимірний фотонно-кристалічний біосенсор на основі кільцевої порожнини. Він призначений для діагностики уражених малярією еритроцитів в діапазоні довжин хвиль
1130-1860 нм для ТМ-поляризованого світла. Пропонований біосенсор складається з двох хвилеводів,
з’єднаних з однією кільцеподібною мікропорожниною, яку отримано видаленням семи отворів решітки, причому мікропорожнина відокремлена від двох хвилеводів трьома отворами. Проникнення аналіту в кільцеподібну порожнину змінює її показник заломлення, і ця зміна показника заломлення
інфікованих і нормальних (неінфікованих) еритроцитів викликає відповідний зсув довжини хвилі на
вихідному терміналі. Робочими параметрами біосенсора є висока чутливість понад 700 нм/RIU, коефіцієнт надвисокої якості (Q-фактор) до 106, що дає добротність датчика до 106 RIU – 1, і низька межа виявлення 10 – 7 RIU. Пропонований пристрій також має ультра-компактний розмір 9,78x8,84 мкм2, що
робить його привабливим для застосування в мікросхеміах. Отримані результати показали, що кільцеподібна конфігурація отворів забезпечує оптичне обмеження в області порожнини. Запропонована
конструкція моделюється за допомогою методу розширення плоскої хвилі (PWE) і алгоритму кінцевої
різниці в часовій області (FDTD). In this paper, a two-dimensional photonic crystal refractive index biosensor based on a ring-shaped cavity has been proposed. It is designed for the diagnosis of malaria-infected red blood cells (RBCs) in the wavelength range of 1130-1860 nm for TM-polarized light. The proposed biosensor consists of two waveguides coupled with one ring-shaped microcavity, which is obtained by removing seven lattice holes, the microcavity is separated from the two waveguides by three holes. The infiltration of the analyte into the ring-shaped cavity changes its refractive index, and this variation of the refractive index of infected and normal uninfected RBCs causes a corresponding wavelength shift at the output terminal. Consequently, a high sensitivity of more than 700 nm/RIU, an ultra-high-quality factor (Q-factor) of up to 106 giving a sensor figure of merit (FOM) of up to 106 RIU – 1, and a low detection limit of 10 – 7 RIU can be achieved for the proposed design. The proposed device has also an ultra-compact size of 9.78 x 8.84 µm2 that makes it so attractive for lab-on-a-chip applications. The obtained results have demonstrated that the ring-shaped holes configuration provides an excellent optical confinement within the cavity region. The proposed design is simulated using Plane Wave Expansion (PWE) method and Finite-Difference Time-Domain (FDTD) algorithm. |
Appears in Collections: |
Журнал нано- та електронної фізики (Journal of nano- and electronic physics) |
Views
Algeria
84264
Brazil
1
China
1984694
Germany
1
India
27364907
Japan
8433220
Poland
1
Singapore
1
Spain
1
Turkey
2327
Ukraine
16871
United Kingdom
2324
United States
16824308
Unknown Country
16870
Downloads
Algeria
84263
China
4134202
Hong Kong SAR China
1
India
23
Indonesia
38
Pakistan
1
Turkey
1
Ukraine
42131
United States
27364909
Unknown Country
1
Files
File | Size | Format | Downloads |
---|---|---|---|
Tayoub_jnep_1_2023.pdf | 752.6 kB | Adobe PDF | 31625570 |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.