Please use this identifier to cite or link to this item: https://essuir.sumdu.edu.ua/handle/123456789/91471
Or use following links to share this resource in social networks: Recommend this item
Title Hydrogen Treatment of Surface Layer of a Gold Film on Glass
Other Titles Воднева обробка поверхневого шару золотої плівки на склі
Authors Vasiljev, A.G.
Vasyliev, T.A.
Zhelezniak, R.O.
Kryvytskyi, V.V.
Doroshenko, T.Р.
ORCID
Keywords електроліз
воднева обробка
воднева крихкість
плівка золота
поверхневий плазмонний резонанс
electrolysis
hydrogen treatment
hydrogen embrittlement
gold film
surface plasmon resonance
Type Article
Date of Issue 2023
URI https://essuir.sumdu.edu.ua/handle/123456789/91471
Publisher Sumy State University
License In Copyright
Citation A.G. Vasiljev, T.A. Vasyliev, R.O. Zhelezniak, et al., J. Nano- Electron. Phys. 15 No 2, 02013 (2023) DOI: https://doi.org/10.21272/jnep.15(2).02013
Abstract Дана робота присвячена вивченню впливу імпульсного насичення воднем на плівку золота на склі, яка використовується як сенсор поверхневого плазмонного резонансу спектрофотометра «Плазмон-6». Внаслідок електролізу в 10 % розчині H2SO4 у воді плівка насичується воднем. Поверхня золотої плівки була катодом, а вугільний електрод – анодом. Імпульси струму електролізу тривали 2 с, а часовий інтервал між імпульсами становив 1800 с. Таким способом було оброблено кілька зразків. Наслідки дії п'яти, десяти, п'ятнадцяти і двадцяти імпульсів на плівку золота розглядалися у вигляді експериментально отриманих спектральних кривих для оброблених зразків. Поверхневий плазмонний резонанс чутливий до змін, що відбуваються в поверхневому шарі датчика поверхневого плазмонного резонансу. Він застосовний для контролю та аналізу змін, викликаних запропонованою обробкою воднем. В експериментах криві плазмонного резонансу зміщувались у більші кути. Тому були зареєстровані зміни оптичних властивостей поверхневого шару золотої плівки. Спостережувані зміни поступово зростали зі збільшенням кількості імпульсів струму електролізу. Математичний підхід до відбиття світла від золотої плівки був виконаний для аналізу змін у поверхневому шарі золотої плівки. Діелектричні властивості поверхневого шару плівки золота оцінювали за допомогою моделі ефективного середовища. Це дозволило змоделювати зміни поверхневого шару плівки, викликані обробкою воднем. В результаті були отримані теоретичні криві плазмонного резонансу. Досягнуто якісної кореляції між експериментально спостережуваними змінами та теоретичними уявленнями про процеси, що відбуваються під час обробки воднем у поверхневому шарі плівки золота на склі.
This work is devoted to the effect of pulse hydrogen saturation on a gold film on glass used as a surface plasmon resonance sensor of the "Plasmon-6" spectrophotometer. Due to electrolysis in a 10 % solution of H2SO4 in water, the film was saturated with hydrogen. The surface of the gold film was the cathode, and the carbon electrode was the anode. Electrolysis current pulses lasted 2 s when the time interval between pulses was 1800 s. In this way, several samples were processed. The consequences of the action of five, ten, fifteen and twenty pulses on a gold film were examined as the experimentally obtained spectral curves for treated samples. The surface plasmon resonance is sensitive to changes occurring in the surface layer of the surface plasmon resonance sensor. It is applicable to control and analyze the changes induced by the proposed hydrogen treatment. In the experiments, the plasmon resonance curves shifted to larger angles. Therefore the optical properties modifications of the surface layer of the gold film were recorded. The observed changes gradually increased with the increase of the number of pulses of the electrolysis current. The mathematical approach to light reflection from the gold film was performed to analyze changes in the surface layer of the gold film. The dielectric properties of the surface layer of the gold film were estimated using the effective medium model. It made it possible to simulate changes in the surface layer of the film induced by hydrogen treatment. As a result, theoretical curves of plasmon resonance were obtained. A qualitative correlation between the experimentally observed changes and the theoretical ideas about the processes occurring during hydrogen treatment in the surface layer of the gold film on glass was achieved.
Appears in Collections: Журнал нано- та електронної фізики (Journal of nano- and electronic physics)

Views

Australia Australia
1
China China
1
Côte d’Ivoire Côte d’Ivoire
1
Ukraine Ukraine
23072
United Kingdom United Kingdom
1744
United States United States
17388
Unknown Country Unknown Country
613

Downloads

China China
23070
France France
1
Germany Germany
1
South Korea South Korea
1
Ukraine Ukraine
23074
United States United States
23070
Unknown Country Unknown Country
1

Files

File Size Format Downloads
Vasiljev_jnep_2_2023.pdf 528,27 kB Adobe PDF 69218

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.